| Windmill Cables | |||
| EPR/HFXLEVA LSOH 0.6/1kV Torsion Resistant Power Cable | HFEPR/HFEVA 0.6/1kV LSOH Screened Torsion Resistant Power Cable | Al Conductor EPR/XLEVA 0.6/1kV LSOH Power Cable 90℃ | more |
Windmill Cables
S-3GSHXOEU HFFR 0.6/1 kV & UL 1000V 90°C
Application
S-3GSHXOEU HFFR 0.6/1 kV & UL 1000V 90°C cables are designed for use at medium mechanical stresses in
wind turbines.
Standards
UL 758
DIN VDE 0250
DIN VED 0282
Construction

Conductor: Stranded bare copper, fine wire class 5 according to IEC 60228 / DIN EN 60228.
Insulation: Rubber compound.
Sheath: EVA.
Technical Data
Rated Voltage Uo/U (Um):600/1000V (DIN VDE 0250)/ 1000V (AWM 758)
Operating Temperatures:-40℃~+90℃
Minimum Bending Radius:flexing: 6×OD; fixed: 4×OD
Short-circuit Temperature:250℃
Flame Retardant:IEC 60332-1
Halogen Free:EN 50267-2-1/IEC 60754
Corrosive Gases:DIN EN 50267-2
Smoke Density:IEC 61034
Oil Resistant:Yes
Cooling Fluid Resistance:Yes
Ozone Resistant:Yes
UV Resistant:Yes
Dimensions and Weight
| Construction | Nominal Overall Diameter | Nominal Weight |
|---|---|---|
| No. of cores×mm² | mm | kg/km |
| 3×1.5 | 10.3 | 142 |
| 4×1.5 | 11.3 | 182 |
| 5×1.5 | 12.5 | 224 |
| 3×2.5 | 12.5 | 217 |
| 4×2.5 | 13.0 | 265 |
| 5×2.5 | 14.5 | 326 |
| 3×4 | 14.5 | 313 |
| 4×4 | 15.5 | 383 |
| 3×6 | 15.5 | 407 |
| 4×6 | 17.5 | 514 |
| 2×10 | 18.5 | 560 |
| 3×10 | 20.0 | 688 |
| 4×10 | 22.0 | 642 |
| 5×10 | 25.5 | 1095 |
| 3×16 | 23.0 | 946 |
| 4×16 | 26.0 | 1242 |
| 5×16 | 28.5 | 1501 |
| 1×25 | 13.0 | 364 |
| 3×25 | 28.0 | 1416 |
| 4×25 | 30.5 | 1746 |
| 5×25 | 34.0 | 2173 |
| 1×35 | 15.0 | 491 |
| 3×35 | 31.5 | 1894 |
| 4×35 | 34.5 | 2338 |
| 5×35 | 38.0 | 2849 |
| 1×50 | 17.0 | 682 |
| 3×50 | 36.0 | 2564 |
| 4×50 | 40.0 | 3236 |
| 5×50 | 44.0 | 3941 |
| 1×70 | 19.5 | 936 |
| 3×70 | 41.5 | 3466 |
| 4×70 | 46.5 | 4504 |
| 5×70 | 51.0 | 5515 |
| 1×95 | 21.5 | 1209 |
| 3×95 | 47.5 | 4580 |
| 1×120 | 24.0 | 1487 |
| 3×120 | 51.0 | 5517 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information